Batteries / LR

LR41

Alkaline zinc / manganese dioxide

Cross-checked Primary battery

Reviewed:

1.5 VNominal voltage
Ø 7.9 × 3.6 mmReference dimensions
Reference dimensions · LR41
LR41Ø 7.9 mm3.6 mm

Reference dimensions are not universal manufacturing tolerances. Check the actual cell and holder.

The type status describes documentary checks of core specifications, not every fact or suitability for a device.

Understanding LR41 before replacement

Identify the actual battery

LR41 is a documented Alkaline zinc / manganese dioxide primary cell with a nominal voltage of 1.5 V. Its reference diameter is 7.9 mm and its reference height is 3.6 mm. These are nominal reference dimensions, not a promise that every manufacturer has identical tolerances.

This dataset describes a non-rechargeable bare cell, without solder tabs or wires. A tabbed or wired assembly requires a separate fit check.

What markings identify this type?

The dataset associates 192, G3A with LR41. The manufacturer may use a different label on the package. These references help identify the type; they do not certify the battery for a particular device.

Similar dimensions in this catalogue

The following types share the same reference diameter as LR41. Their height, chemistry or voltage may differ. They are comparisons, not approved substitutes:

  • PR41 — PR41: 3.6 mm high, 1.4 V; Zinc–air.
  • SR41 — SR41: 3.6 mm high, 1.55 V; Silver oxide / zinc.
  • SR731 — SR731: 3.1 mm high, 1.55 V; Silver oxide / zinc.

What to check before replacing LR41

Read the original device marking, verify nominal voltage and chemistry, compare diameter and height, and check the contacts and load requirements. Same diameter, identical voltage, or a familiar brand prefix alone is not enough to establish interchangeability.

The available data contains no affirmative device-specific fit test for LR41. A missing compatibility relation means “not assessed,” not “compatible.”

How reliable are these specifications?

Core type characteristics were compared with primary material from at least two independent publishers. This does not verify all model-specific values or physical suitability.

Technical specifications

DesignationLR41
Cross-checked using documents from two independent publishers [Energizer] [Maxell] [Maxell]
ChemistryAlkaline zinc / manganese dioxide
Cross-checked using documents from two independent publishers [Energizer] [Maxell]
Nominal voltage1.5 V (Nominal)
Cross-checked using documents from two independent publishers [Energizer] [Maxell]
Diameter7.9 mm
Cross-checked using documents from two independent publishers [Energizer] [Maxell]
Height3.6 mm
Cross-checked using documents from two independent publishers [Energizer] [Maxell]
RechargeableNo
Documented source [Energizer]
Terminal formBare cell without tabs or leads
Curator assessment [Energizer]

Reference dimensions are not universal manufacturing tolerances. Check the actual cell and holder.

Other designations

These codes identify the same type family. Match the load variant, terminals and device requirements separately.

Documented brands

EnergizerMaxell

Brand presence comes from product documents or documented code mappings; current availability is not checked.

Product-specific observations

Capacity belongs to an individual product and test regime. It is not a universal value for this battery type.

Energizer 192Historical document

Current availability not checked [Energizer]

Capacity45 mAh (Typical)
Historical manufacturer data (obsolete document) [Energizer]
Test resistance15,000 Ω
Historical manufacturer data (obsolete document) [Energizer]
Cutoff voltage0.9 V
Historical manufacturer data (obsolete document) [Energizer]
Test temperature21 °C
Historical manufacturer data (obsolete document) [Energizer]
Test scheduleContinuous discharge
Historical manufacturer data (obsolete document) [Energizer]
Weight0.5 g (Typical)
Historical manufacturer data (obsolete document) [Energizer]
Minimum product diameter7.55 mm
Historical manufacturer data (obsolete document) [Energizer]
Maximum product diameter7.9 mm
Historical manufacturer data (obsolete document) [Energizer]
Minimum product height3.3 mm
Historical manufacturer data (obsolete document) [Energizer]
Maximum product height3.6 mm
Historical manufacturer data (obsolete document) [Energizer]
Maxell LR41Documented source

Current availability not checked [Maxell] [Maxell]

Capacity25 mAh (Nominal)
Documented source [Maxell]
Test current0.07 mA
Documented source [Maxell]
Cutoff voltage1.2 V
Documented source [Maxell]
Test temperature20 °C
Documented source [Maxell]
Test scheduleContinuous discharge
Documented source [Maxell]

Replacement limits

Device compatibility has not been verified. Dimensions alone do not prove that a battery fits or works.

Replacement evidence by category

Other markings of this technical type

192 · G3A

These markings resolve to this type in documented sources. The exact variant and device requirements still matter.

Conditional replacement: review requirements

No conditional cross-type relation is recorded.

Known obstacles to direct replacement

No explicit obstacle is recorded here; that is not evidence of compatibility.

Other type pairs without a recorded assessment

This pair has not been assessed. No compatibility conclusion is available.

No automatic replacement recommendation. Device compatibility has not been verified. Dimensions alone do not prove that a battery fits or works.

Documentary limits

Energizer 192 is documented as obsolete. Its observations are historical; Maxell independently supports the LR41 core specifications.

Compare batteries

Sources & verification

  • Energizer · en-192 Historical document

    Energizer LR41 product datasheet
    EBC - 4405G Page 1 of 1 · Reviewed:

    Current availability not checked
  • Maxell · maxell-sr-lr Documented source

    Silver Oxide Batteries (SR) / Alkaline Button Batteries (LR)
    · Reviewed:

    Current availability not checked
  • Maxell · maxell-crossref Documented source

    Micro Battery Cross Reference and Replacement Guide
    October 2017 · Reviewed:

    Current availability not checked
  • Energizer · energizer-primary Documented source

    Battery Comparison Chart: primary and rechargeable batteries
    · Reviewed:

    Current availability not checked

Common questions

What size is LR41?

Ø 7.9 × 3.6 mm

Can LR41 be recharged?

No. Do not charge primary cells.

Can LR41 replace another battery?

Not on the basis of size or matching names alone. Check the exact device requirements and the directed compatibility notes. This catalogue does not contain a guaranteed device-fit recommendation for LR41.

How does LR41 differ from PR41?

LR41 and PR41 have reference heights of 3.6 mm and 3.6 mm respectively, and nominal voltages of 1.5 V and 1.4 V. Their chemical systems are Alkaline zinc / manganese dioxide and Zinc–air. These comparisons do not establish a permitted replacement.

Open technical comparison: PR41

This is a technical comparison, not an equivalence or fit certificate.